Galvonic Isolator

The Main Sand Box for bertram31.com

Moderators: CaptPatrick, mike ohlstein, Bruce

Post Reply
Bill Mckinnon
Senior Member
Posts: 117
Joined: Jun 29th, '06, 13:17
Location: Charleston SC

Galvonic Isolator

Post by Bill Mckinnon »

Just want to check with you guys. Picked the isolator up and am ready to install. The only question is does it need to be connected to the bonding system on the boat. Looked at the building tips section but just want to be sure

Thanks

Capt. Bill McKinnon
Charlesron SC
User avatar
CaptPatrick
Founder/Admin
Posts: 4161
Joined: Jun 7th, '06, 14:25
Location: 834 Scott Dr., LLANO, TX 78643 - 325.248.0809 bertram31@bertram31.com

Post by CaptPatrick »

Bill.

Emphatically NO. The galvanic isolator is part of your AC electrical system and is only grounded to the main AC ground.

Br,

Patrick
User avatar
Bruce
Site Admin
Posts: 3789
Joined: Jun 29th, '06, 12:04
Location: Palm Beach Gardens, Fl.

Post by Bruce »

Actualy Pat thats not correct.

The isolator permits ac currents but blocks the dc currents that can occur because of boats with dissimilar metals in the water.

One terminal is the shore ground, the other is the boat ground and AC ground which is all tied together. Since the engines are tied to the bonding system, that ties everything to the boat side of the isolator.

Take a look at the Guest paper work and wiring diagram from Patricks boat. I believe its in the generator folder.
User avatar
CaptPatrick
Founder/Admin
Posts: 4161
Joined: Jun 7th, '06, 14:25
Location: 834 Scott Dr., LLANO, TX 78643 - 325.248.0809 bertram31@bertram31.com

Post by CaptPatrick »

Know you're right Bro, in that indirectly it's tied to the bonding system and negative battery through the engine ground. My point was really that the isolater isn't directly wired into the bonding system...

Sorry for being inconcise.
Bill Mckinnon
Senior Member
Posts: 117
Joined: Jun 29th, '06, 13:17
Location: Charleston SC

Galvonic Isolator

Post by Bill Mckinnon »

Thanks Guys, The way i read the diagram is the ac ground is tied to the negative ground on the engine or the battery. That way all grounds on the boat are connected. If i am not right let me know

Thanks

Bill[/b]
User avatar
Bruce
Site Admin
Posts: 3789
Joined: Jun 29th, '06, 12:04
Location: Palm Beach Gardens, Fl.

Post by Bruce »

Bill,
You are correct.
babycakes
Posts: 20
Joined: Nov 5th, '06, 20:43
Location: Crownsville, Maryland

Post by babycakes »

Thats what makes this site so great, being humble when a mistake is made.
Post Reply

Who is online

Users browsing this forum: Bing [Bot] and 247 guests