engines

The Main Sand Box for bertram31.com

Moderators: CaptPatrick, mike ohlstein, Bruce

Post Reply
IRGuy
Senior Member
Posts: 1767
Joined: Jun 29th, '06, 07:48
Location: Wilmington, NC

Post by IRGuy »

Questiion please.. What are the stringers made of?
Frank B
1983 Bertram 33 FBC "Phoenix"
--------------
Trump lied! Washington DC isn't a swamp.. it is a cesspool!
User avatar
Ironman
Senior Member
Posts: 527
Joined: Jun 30th, '06, 11:06

Post by Ironman »

Nice... What HP Cummins?
Powder coated Alumn. stringer caps?

Keep the pics comin.
Wayne
jspiezio
Senior Member
Posts: 882
Joined: Nov 25th, '07, 07:21
Location: Long Island, NY

Post by jspiezio »

Very sweet.
User avatar
Charlie J
Senior Member
Posts: 2207
Joined: Jun 29th, '06, 09:14
Location: freeport n.y

Post by Charlie J »

very nice john, best of luck with her
User avatar
John F.
Senior Member
Posts: 2114
Joined: Jun 29th, '06, 07:58

Post by John F. »

First class. Nice door too.
User avatar
Harry Babb
Senior Member
Posts: 2354
Joined: Jun 30th, '06, 21:45
Location: Fairhope Al
Contact:

Post by Harry Babb »

Beautiful work ! ! ! It's nice when it's all clean............

I know you are getting anxious to hear those puppies run.

Harry
hb
User avatar
gplume
Senior Member
Posts: 455
Joined: Jan 2nd, '07, 21:23
Location: North Scituate, RI

Post by gplume »

Yes...nice work...I could eat diner off those bilge floors.

Keep the pictures coming a s you progress.
Giff
User avatar
bob lico
Senior Member
Posts: 5278
Joined: Jun 29th, '06, 19:22
Location: sayville,long island

Post by bob lico »

ok i will bite. why would you connect both battery switches with positive cable? other then that nice clean installation.ok john from the top ; best method port engine dedicated battery ,starboard dedicated battery,then dedicated house battery. that is 3 seperate on /off 500 amp rated switches.second best; engine dedicated battery and dedicated house battery two on/ off switches (a little insurance would be a 500 ampere rated solonoid to parallel both battery banks) .third and last would be two battery with two switches .never consider a switch with a 1,2 off in a diesel installation.a connection between two switches could give murphy law the edge.
capt.bob lico
bero13010473
User avatar
Kevin
Senior Member
Posts: 1070
Joined: Jul 2nd, '06, 19:29
Location: Just north of South Florida

Post by Kevin »

Bob,
Can you explain the whole never use a switch with 1,2,off. Mine also have 'Both". I think they are rated for 500 amps. Thanks
User avatar
bob lico
Senior Member
Posts: 5278
Joined: Jun 29th, '06, 19:22
Location: sayville,long island

Post by bob lico »

kevin if you allready own them prior to diesel installation keep them if they are rated 500 ampere.diesel engines are going to need at least a battery rated 500 ampere or more for starting or you might say 4d or multible battery bank .however remove any cables between switches and use 1,2, both as a simple on/off .in case of a short you would have a disaster.and at the very least you want to prevent one battery draining the other due to a unknown electrical fault or leaving a heavy electrical drawing loat connected.connection of two batterys by way of a solonoid still gives you isolation and a back up shoud one battery go dead at sea.i also recomend using a charger with isolation and isolation blocks. dead battery at sea is something you have to avoid at all possible costs by planning the battery system during installation you can avoid all the pitfalls.a gasser starts will a hell of alot less battery power.kevin the subject is vast if you want me to be more detailed just asked what part of the battery layout you want me to explain. you in particular go far offshore and need a foolproof system.
capt.bob lico
bero13010473
User avatar
bob lico
Senior Member
Posts: 5278
Joined: Jun 29th, '06, 19:22
Location: sayville,long island

Post by bob lico »

kevin you have 4d batterys don`t you. just sit back and think about the available short circuit or if one battery becomes grounded .with two 4d batterys you have available 2200 ampere you don`t want to depend on that 500 ampere switch to hold that current ----instant fire!!! take two switches and isolate them to there repective battery and you have half that current on one switch.NO INTERCONNECTING CABLE. you also have the ability to start engine on the other battery should one go bad.
capt.bob lico
bero13010473
User avatar
Bertramp
Senior Member
Posts: 1430
Joined: Jan 2nd, '09, 14:57
Location: Sag Harbor, NY Fort Lauderdale, FL
Contact:

Post by Bertramp »

I've slept in places not as nice as that bilge !!
User avatar
Dug
Senior Member
Posts: 2256
Joined: Jun 29th, '06, 11:04
Location: Worcester, MA

Post by Dug »

Very, very nice. I want your door!!!!
User avatar
Kevin
Senior Member
Posts: 1070
Joined: Jul 2nd, '06, 19:29
Location: Just north of South Florida

Post by Kevin »

When I get home I need to post some pics of mywire job. I will start another thread for it though.

Oh yeah, I am a bit jealous of that engine space too!