3208 question

The Main Sand Box for bertram31.com

Moderators: CaptPatrick, mike ohlstein, Bruce

Post Reply
steve miller
Senior Member
Posts: 157
Joined: Aug 29th, '06, 21:40
Location: block Island R.I.
Contact:

3208 question

Post by steve miller »

I was running antifreeze through my raw water system to winterize the boat, the engine started to turn slowly, as if the batteries were low. I charged 'em up. Same thing. The wire going from the starter to the bonding system got HOT.....like melt the plastic hot. Any ideas?
I have not had any problems with charging, or the starter. It happened very suddenly, one second turning over fine, the next second........not.
Thanks in advance for any help.
Steve
User avatar
In Memory of Vicroy
Senior Member
Posts: 2340
Joined: Jun 29th, '06, 09:19
Location: Baton Rouge, LA

Post by In Memory of Vicroy »

Check all your battery cable connections on both ends first....remove, wire brush or scrape with a knife, shoot with CX and re assemble. The fact that the wire is getting that hot indicates a lot of current is flowing, so might be a dragging starter.

UV
steve miller
Senior Member
Posts: 157
Joined: Aug 29th, '06, 21:40
Location: block Island R.I.
Contact:

Post by steve miller »

Thanks, Vic. I've been waiting for a spot of good weather, in vain, to try your suggestion. BTW, what are the ramifications of a "dragging" starter? Rust? crapped out entirely? Not something I have encountered yet.
Steve
User avatar
Rawleigh
Senior Member
Posts: 3444
Joined: Jun 29th, '06, 08:30
Location: Irvington, VA

Post by Rawleigh »

Bendix stuck extended. It could be corrosion or a broken return spring.
Rawleigh
1966 FBC 31
User avatar
John F.
Senior Member
Posts: 2114
Joined: Jun 29th, '06, 07:58

Post by John F. »

...and after a brief respite, Steve is back to the joys of boat owndership....
User avatar
In Memory Walter K
Senior Member
Posts: 2912
Joined: Jun 30th, '06, 21:25
Location: East Hampton LI, NY
Contact:

Post by In Memory Walter K »

Take it out, spray with CX if it's a stuck or lazy Bendix. Actually a few hammer taps sometimes works.Once you've gone through the trouble of taking it out, you might as well have it bench tested at an alternater/starter rebuilder.
steve miller
Senior Member
Posts: 157
Joined: Aug 29th, '06, 21:40
Location: block Island R.I.
Contact:

Post by steve miller »

I've seen starters where the bendix got stuck in the out position-the starter kept going after the engine was running, and burned out. But the starter ran at the usual speed! I should be able to see it without taking it off, yes?
User avatar
Bruce
Site Admin
Posts: 3789
Joined: Jun 29th, '06, 12:04
Location: Palm Beach Gardens, Fl.

Post by Bruce »

The wire you say goes from the starter to the bonding system should be tied to the battery ground.

It sounds like the ground cable feed from the battery is bad and its trying to get the ground thru the bonding wire.

Since its a much smaller guage wire, reason for getting hot, that could be why the starter is turning over slowly because its not seeing the proper amperage.
User avatar
Rawleigh
Senior Member
Posts: 3444
Joined: Jun 29th, '06, 08:30
Location: Irvington, VA

Post by Rawleigh »

I knew the expert would get it!!! Good catch Bruce! Bad negative battery wire!
Rawleigh
1966 FBC 31
steve miller
Senior Member
Posts: 157
Joined: Aug 29th, '06, 21:40
Location: block Island R.I.
Contact:

Post by steve miller »

Thanks Bruce!! That sounds like the truth
I take back what I said about you needing to get out more
'cause of the "Christmas" thread. (LOL!!)
User avatar
In Memory Walter K
Senior Member
Posts: 2912
Joined: Jun 30th, '06, 21:25
Location: East Hampton LI, NY
Contact:

Post by In Memory Walter K »

What a site!
Post Reply

Who is online