bonding through hull fittings

The Main Sand Box for bertram31.com

Moderators: CaptPatrick, mike ohlstein, Bruce

Post Reply
User avatar
CaptPatrick
Founder/Admin
Posts: 4161
Joined: Jun 7th, '06, 14:25
Location: 834 Scott Dr., LLANO, TX 78643 - 325.248.0809 bertram31@bertram31.com

Post by CaptPatrick »

John,

8 ga tinned, marine grade, wire is the minimun requirement that should be used for connecting various items to the bonding system. It is preferable to solder all lugs to the wire & use adhesive linned heat shrink tubing to further protect the lug attachment.

12 ga is way too small.

Every metal object that is in contact with the water the boat sits in should be bonded...

Br,

Patrick
Tony Meola
Senior Member
Posts: 7036
Joined: Jun 29th, '06, 21:24
Location: Hillsdale, New Jersey
Contact:

Post by Tony Meola »

John

If you need the copper bonding strap, try www.gacopper.com. In June before the price increase they had the best price I could find on the internet.
User avatar
JohnD
Senior Member
Posts: 409
Joined: Jun 29th, '06, 09:48
Location: Baltimore, MD

Post by JohnD »

Good link Tony!

Tony or Capt Patrick, what would be a good thickness .011, .022, .032?

Some of my bonding got abused during my repower and I'd like to replace it this winter.

Thanks,
JohnD
Tony Meola
Senior Member
Posts: 7036
Joined: Jun 29th, '06, 21:24
Location: Hillsdale, New Jersey
Contact:

Post by Tony Meola »

John

This is from the tip section:

"The primary strip should be copper at least 26 gauge in thickness and 1" in width. "

That would be the .22 thikness which is what they had when I ordered mine not the heavier one they have now. I would think the heavier one might be harder to work with when making the conection points.