wire sleeving

The Main Sand Box for bertram31.com

Moderators: CaptPatrick, mike ohlstein, Bruce

Post Reply
my other east
Senior Member
Posts: 92
Joined: Aug 15th, '12, 08:53
Location: on some list...

wire sleeving

Post by my other east »

good morning Faithful.
i'm getting ready to finish up the wiring, and was wondering what you guys are using for sleeving.
i refuse to use the plastic crap they sell at the auto parts store.
as always, thank you in advance
Eric Vincent
1974 31 FBC hull # 315-1442
User avatar
Rawleigh
Senior Member
Posts: 3444
Joined: Jun 29th, '06, 08:30
Location: Irvington, VA

Re: wire sleeving

Post by Rawleigh »

The mesh works pretty good and allows any water to drip on through.

http://www.cabletiesandmore.com/BraidedSleeving.php
Rawleigh
1966 FBC 31
IRGuy
Senior Member
Posts: 1767
Joined: Jun 29th, '06, 07:48
Location: Wilmington, NC

Re: wire sleeving

Post by IRGuy »

I have made a lot of wiring changes on my boat over the years, removing/revising the existing as well as adding new circuits. I use the split corrugated plastic sleeving whenever the physical conditions allow. I feel this is the best system for the following reasons...

- It can be applied over existing wiring without having to detach either end of the circuit

- Long wiring runs can be installed and branches off the main run can be handled by simply pulling wires through the split where desirable

- I have no experience with the woven mesh sleeving but it would seem to me the installer would have to cut the mesh to length and then feed the various wires into one end of the sleeve and along the sleeve to the other end. This adds another step to the installation process.

Regardless of which sleeve system is used I believe there is a specific requirement that marine wiring should be supported at regular intervals to keep it in place. I am not sure what the suggested support spacing is, but I try to have support every 12" whenever possible. I am sure Pete Fallon, as a experienced yacht surveyor, could shed more light on this subject.

I have no qualms if someone chooses to use the woven sleeving, it just seems to me while the finished product is certainly satisfactory the process installing it is a little more complicated.
Frank B
1983 Bertram 33 FBC "Phoenix"
--------------
Trump lied! Washington DC isn't a swamp.. it is a cesspool!
Tony Meola
Senior Member
Posts: 7036
Joined: Jun 29th, '06, 21:24
Location: Hillsdale, New Jersey
Contact:

Re: wire sleeving

Post by Tony Meola »

I used the plastic split loom also, except you need to make sure it is fire retardant. The last link is a fire wrap hook and loop that looks interesting.

https://www.delcity.net/store/Loom-&-Loom-Clamps/
https://www.delcity.net/store/Flame-Ret ... m/p_811448
https://www.delcity.net/store/High!Temp ... m/p_811350
https://www.delcity.net/store/Fire-Flex ... 3.h_819484
1975 FBC BERG1467-315
User avatar
Joseph Fikentscher
Senior Member
Posts: 610
Joined: Jun 29th, '06, 07:36
Location: Southport, NC
Contact:

Re: wire sleeving

Post by Joseph Fikentscher »

Sea Hunt Triton 207, a step down, but having fun till my next Bertram!

[url]https://www.instagram.com/endurance_ber ... hl=en/[url]